{"id":13566,"date":"2020-03-09T20:16:15","date_gmt":"2020-03-09T19:16:15","guid":{"rendered":"https:\/\/geothermie-schweiz.ch\/?p=13566"},"modified":"2020-03-09T20:16:15","modified_gmt":"2020-03-09T19:16:15","slug":"un-systeme-de-chauffage-geothermique-des-aiguillages","status":"publish","type":"post","link":"https:\/\/geothermie-schweiz.ch\/fr\/un-systeme-de-chauffage-geothermique-des-aiguillages\/","title":{"rendered":"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages"},"content":{"rendered":"<p><strong>Est-ce qu\u2019il existera bient\u00f4t des chauffages des aiguillages qui ne consommeront presque plus d\u2019\u00e9lectricit\u00e9 gr\u00e2ce \u00e0 la g\u00e9othermie ? Une installation de d\u00e9monstration g\u00e9othermique et une \u00e9tude fournissent des conclusions int\u00e9ressantes \u00e0 des niveaux tr\u00e8s divers.<\/strong><!--more--><\/p>\n<p>Le but de l\u2019\u00e9tude soutenue par l\u2019Office f\u00e9d\u00e9ral des transports (OFT) \u00e9tait de d\u00e9terminer si la g\u00e9othermie pouvait \u00eatre une alternative aux chauffages des aiguillages \u00e9lectriques ou fonctionnant au gaz. L\u2019exploitation a montr\u00e9 que l\u2019installation-pilote ne s\u2019est pas av\u00e9r\u00e9e plus efficiente qu\u2019une installation \u00e9lectrique moderne. Cela s\u2019explique par plusieurs facteurs, dont certains peuvent \u00eatre am\u00e9lior\u00e9s, en particulier : la consommation \u00e9lev\u00e9e de courant en mode veille, une transmission insuffisante de la chaleur et une commande de l\u2019installation qui n\u2019est pas encore optimale.<\/p>\n<div id=\"attachment_13560\" style=\"width: 810px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg\" rel=\"lightbox-0\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13560\" class=\"wp-image-13560 size-full\" src=\"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg\" alt=\"Quelle: Triples-Systeme GmbH\" width=\"800\" height=\"600\" srcset=\"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg 800w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-300x225.jpg 300w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-768x576.jpg 768w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-776x582.jpg 776w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-565x424.jpg 565w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-412x309.jpg 412w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-352x264.jpg 352w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-332x249.jpg 332w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-267x200.jpg 267w, https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach-635x476.jpg 635w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/a><p id=\"caption-attachment-13560\" class=\"wp-caption-text\">Source: Triples-Systeme GmbH<\/p><\/div>\n<p><strong>Les CFF poursuivent l\u2019exploitation de l\u2019installation<br \/>\n<\/strong>Un autre d\u00e9fi, encore non r\u00e9solu, r\u00e9side dans l\u2019incapacit\u00e9 de l\u2019installation \u00e0 emp\u00eacher le gel des branchements lors des grands froids. Les CFF poursuivent l\u2019exploitation de l\u2019installation afin de d\u00e9terminer dans quelle mesure elle peut \u00eatre optimis\u00e9e sur le plan technique et de l\u2019exploitation.<\/p>\n<p><strong>Plus d&rsquo;informations<br \/>\n<\/strong><\/p>\n<ul>\n<li><a href=\"https:\/\/www.bav.admin.ch\/dam\/bav\/de\/dokumente\/themen\/umwelt\/energiestrategie-projekte\/kurzbeschrieb_083.pdf.download.pdf\/Kurzbeschrieb%20P-083.pdf\" target=\"_blank\" rel=\"noopener\"><span style=\"text-decoration: underline;\">Fiche de projet OFT<\/span><\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Est-ce qu\u2019il existera bient\u00f4t des chauffages des aiguillages qui ne consommeront presque plus d\u2019\u00e9lectricit\u00e9 gr\u00e2ce \u00e0 la g\u00e9othermie ? Une installation de d\u00e9monstration g\u00e9othermique et une \u00e9tude fournissent des conclusions [&hellip;]<\/p>\n","protected":false},"author":12,"featured_media":13561,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":"","_links_to":"","_links_to_target":""},"categories":[692],"tags":[],"class_list":["post-13566","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-projet-de-demonstration"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages - G\u00e9othermie-Suisse<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages - G\u00e9othermie-Suisse\" \/>\n<meta property=\"og:description\" content=\"Est-ce qu\u2019il existera bient\u00f4t des chauffages des aiguillages qui ne consommeront presque plus d\u2019\u00e9lectricit\u00e9 gr\u00e2ce \u00e0 la g\u00e9othermie ? Une installation de d\u00e9monstration g\u00e9othermique et une \u00e9tude fournissent des conclusions [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/\" \/>\n<meta property=\"og:site_name\" content=\"G\u00e9othermie-Suisse\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-09T19:16:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Geothermie Admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Geothermie Admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/\"},\"author\":{\"name\":\"Geothermie Admin\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#\\\/schema\\\/person\\\/c8f269239d9dad84257caae2486aba78\"},\"headline\":\"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages\",\"datePublished\":\"2020-03-09T19:16:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/\"},\"wordCount\":229,\"publisher\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/wp_live\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Bahnhof_Eschenbach.jpg\",\"articleSection\":[\"Projet de d\u00e9monstration\"],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/\",\"url\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/\",\"name\":\"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages - G\u00e9othermie-Suisse\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/wp_live\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Bahnhof_Eschenbach.jpg\",\"datePublished\":\"2020-03-09T19:16:15+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#primaryimage\",\"url\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/wp_live\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Bahnhof_Eschenbach.jpg\",\"contentUrl\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/wp_live\\\/wp-content\\\/uploads\\\/2020\\\/03\\\/Bahnhof_Eschenbach.jpg\",\"width\":800,\"height\":600},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/geothermische-weichenheizung-muss-noch-optimiert-werden\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#website\",\"url\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/\",\"name\":\"Geothermie Schweiz\",\"description\":\"Dachverband der Schweizer Geothermie\",\"publisher\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#organization\"},\"alternateName\":\"Dachverband der Schweizer Geothermie\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#organization\",\"name\":\"Geothermie Schweiz\",\"alternateName\":\"Dachverband der Schweizer Geothermie\",\"url\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/wp_live\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/GeothermieSuisse_Logo_Couleurs_RVB_72dpi.png\",\"contentUrl\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/wp_live\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/GeothermieSuisse_Logo_Couleurs_RVB_72dpi.png\",\"width\":843,\"height\":186,\"caption\":\"Geothermie Schweiz\"},\"image\":{\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/#\\\/schema\\\/person\\\/c8f269239d9dad84257caae2486aba78\",\"name\":\"Geothermie Admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b0c59651dce4522ea5b04b70f5e5bb12996448e7bd4f75b123d770a47918e046?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b0c59651dce4522ea5b04b70f5e5bb12996448e7bd4f75b123d770a47918e046?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b0c59651dce4522ea5b04b70f5e5bb12996448e7bd4f75b123d770a47918e046?s=96&d=mm&r=g\",\"caption\":\"Geothermie Admin\"},\"url\":\"https:\\\/\\\/geothermie-schweiz.ch\\\/fr\\\/author\\\/geothermie-admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages - G\u00e9othermie-Suisse","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/","og_locale":"fr_FR","og_type":"article","og_title":"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages - G\u00e9othermie-Suisse","og_description":"Est-ce qu\u2019il existera bient\u00f4t des chauffages des aiguillages qui ne consommeront presque plus d\u2019\u00e9lectricit\u00e9 gr\u00e2ce \u00e0 la g\u00e9othermie ? Une installation de d\u00e9monstration g\u00e9othermique et une \u00e9tude fournissent des conclusions [&hellip;]","og_url":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/","og_site_name":"G\u00e9othermie-Suisse","article_published_time":"2020-03-09T19:16:15+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg","type":"image\/jpeg"}],"author":"Geothermie Admin","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Geothermie Admin","Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#article","isPartOf":{"@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/"},"author":{"name":"Geothermie Admin","@id":"https:\/\/geothermie-schweiz.ch\/#\/schema\/person\/c8f269239d9dad84257caae2486aba78"},"headline":"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages","datePublished":"2020-03-09T19:16:15+00:00","mainEntityOfPage":{"@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/"},"wordCount":229,"publisher":{"@id":"https:\/\/geothermie-schweiz.ch\/#organization"},"image":{"@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#primaryimage"},"thumbnailUrl":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg","articleSection":["Projet de d\u00e9monstration"],"inLanguage":"fr-FR"},{"@type":"WebPage","@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/","url":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/","name":"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages - G\u00e9othermie-Suisse","isPartOf":{"@id":"https:\/\/geothermie-schweiz.ch\/#website"},"primaryImageOfPage":{"@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#primaryimage"},"image":{"@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#primaryimage"},"thumbnailUrl":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg","datePublished":"2020-03-09T19:16:15+00:00","breadcrumb":{"@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#primaryimage","url":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg","contentUrl":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2020\/03\/Bahnhof_Eschenbach.jpg","width":800,"height":600},{"@type":"BreadcrumbList","@id":"https:\/\/geothermie-schweiz.ch\/geothermische-weichenheizung-muss-noch-optimiert-werden\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/geothermie-schweiz.ch\/fr\/"},{"@type":"ListItem","position":2,"name":"Un syst\u00e8me de chauffage g\u00e9othermique des aiguillages"}]},{"@type":"WebSite","@id":"https:\/\/geothermie-schweiz.ch\/#website","url":"https:\/\/geothermie-schweiz.ch\/","name":"Geothermie Schweiz","description":"Dachverband der Schweizer Geothermie","publisher":{"@id":"https:\/\/geothermie-schweiz.ch\/#organization"},"alternateName":"Dachverband der Schweizer Geothermie","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/geothermie-schweiz.ch\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/geothermie-schweiz.ch\/#organization","name":"Geothermie Schweiz","alternateName":"Dachverband der Schweizer Geothermie","url":"https:\/\/geothermie-schweiz.ch\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/geothermie-schweiz.ch\/#\/schema\/logo\/image\/","url":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2024\/09\/GeothermieSuisse_Logo_Couleurs_RVB_72dpi.png","contentUrl":"https:\/\/geothermie-schweiz.ch\/wp_live\/wp-content\/uploads\/2024\/09\/GeothermieSuisse_Logo_Couleurs_RVB_72dpi.png","width":843,"height":186,"caption":"Geothermie Schweiz"},"image":{"@id":"https:\/\/geothermie-schweiz.ch\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/geothermie-schweiz.ch\/#\/schema\/person\/c8f269239d9dad84257caae2486aba78","name":"Geothermie Admin","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/b0c59651dce4522ea5b04b70f5e5bb12996448e7bd4f75b123d770a47918e046?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b0c59651dce4522ea5b04b70f5e5bb12996448e7bd4f75b123d770a47918e046?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b0c59651dce4522ea5b04b70f5e5bb12996448e7bd4f75b123d770a47918e046?s=96&d=mm&r=g","caption":"Geothermie Admin"},"url":"https:\/\/geothermie-schweiz.ch\/fr\/author\/geothermie-admin\/"}]}},"_links":{"self":[{"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/posts\/13566","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/users\/12"}],"replies":[{"embeddable":true,"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/comments?post=13566"}],"version-history":[{"count":0,"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/posts\/13566\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/media\/13561"}],"wp:attachment":[{"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/media?parent=13566"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/categories?post=13566"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/geothermie-schweiz.ch\/fr\/wp-json\/wp\/v2\/tags?post=13566"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}